Numerical simulations of 3D turbulent flow in a large-bore axial-flow pump coupled with half-elbow suction sump were perlbrmed by using CFD approach. The numerical model and velocity and pressure distributions in entire flow passage were presented. The obvious backflow in half-elbow suction sump and strong flow nonuniformity at suction sump outlet were observed, whereas these phenomena were not observed in existing studies performed for a separate suction sump by either experimental or numerical approach. This result indicates that the interaction between half-elbow suction sump and impeller has significant effect on the flow distribution in the pump passage. The change of pump efficiency caused by the interaction was discussed,
WANG Fu-jun LI Yao-jun CONG Guo-hui WANG Wen-e WANG Hai-song